866.424.7622
sales@unimaclp.com

 

Base Mounted

B Series packages can accommodate multiple blower styles and profiles, select "Blowers" above for more information

The “Base Mounted” design features 3/8” steel plate formed into a elevated base providing a rigid mounting platform for the blower, motor and discharge silencer.

The B series is a family of PD blower packages from 2 HP to 20 HP with pressures to 15 PSI. For each model, proper blower selection is made by carefully considering bearing life, % of max. pressure, speed, temperature rise, and noise level.

Base Mounted Literature

Combination inlet silencer - filter incorporates multiple silencing tubes around the outside of the base and a central tubular steel acoustic section layered with absorptive media for maximum attenuation. A dry type replaceable element removes 99% of particles 2 micron and larger.

Discharge silencers reduce the noise and pulsation energy generated by the blower. An all welded steel absorptive style discharge silencer has minimal pressure drop and provides insertion loss levels between 10 to 45 dB across the frequency bands.The silencer is positioned as close to the blower connection as possible to maximize effectiveness.

The relief valve is rated for the full capacity of the blower. The diaphragm assist spring loaded design maintains repeatable set pressures after numerous cycles.

Motor nameplate HP is not exceeded even at relief valve settings. This leaves a 15% service factor for extra safety. All inlet and discharge losses of the filter, silencers and check valves are factored in the performance calculations.

Belt drives are designed for maximum belt life and minimum bearing load, with a service factor of 150 to 200 % used.

A number of options are available to “customize” the package for your application.


Standard Equipment
  • Pressure or Vacuum
  • PD Lobe Blower
  • Synthetic lubricant fill
  • Drive motor
  • V-Belt or Direct drive
  • Totally enclosed guard
  • Oversized inlet silencer filter
  • Full flow relief valve
  • Gauge, Pressure or Vacuum
  • Discharge silencer, absorptive
  • Flexible connector
  • Formed steel plate mounting base
  • Drawings, operating manuals

 